RFQ Builder
Equipment findings organized by vendor category for RFQ preparation.
Controllers
5 itemsMotion controllers, drives, and dispatch systems
Hotel BOH: Modernize elevator nos. BRS1, BRS2, EP1 and EP2 with new MRL gearless machines, new controllers, positioning system, door operators and equipment, hall door equipment, signals and fixtures, hoistway wiring, cab components and recondition other equipment as specified.
Hotel BOH: Modernize elevator no. BRF1 with new gearled machine, new controller, positioning system, door operators and equipment, hall door equipment, signals and fixtures, hoistway wiring, cab components and recondition other equipment as specified.
Communication circuit: Telephone circuit terminated at junction box of each controller.
Motor Drive Units: Provide New, Regenerative
Provide for elevators as scheduled. When power is lost in a building, the unit will disconnect the elevator system from the building power source. It will then power up its inverter and provide battery generated three (3) phase power to the elevator controller.
Door Equipment
14 itemsDoor operators, entrances, frames, sills, and hardware
Hotel Tower 1: Modernize elevator nos. TP1-TP6 with new controls, new gearless machines, positioning system, door operators and equipment, governor, signals and fixtures, hoistway wiring, cab interiors, and recondition other equipment as specified.
Hotel BOH: Modernize elevator nos. BRS1, BRS2, EP1 and EP2 with new MRL gearless machines, new controllers, positioning system, door operators and equipment, hall door equipment, signals and fixtures, hoistway wiring, cab components and recondition other equipment as specified.
Hotel BOH: Modernize elevator no. BRF1 with new gearled machine, new controller, positioning system, door operators and equipment, hall door equipment, signals and fixtures, hoistway wiring, cab components and recondition other equipment as specified.
Restaurant Kitchens: Modernize elevator nos. KS2, KS3, KS4, KS5, KS7 with new controls, new pumping units, positioning system, door operators and equipment, signals and fixtures, hoistway wiring, cab components, and recondition other equipment as specified.
Theatre: Modernize elevator no. CTS1 with new pumping unit and tank, new controls, positioning system, door operator and equipment, signals and fixtures, hoistway wiring, cab components and recondition other equipment as specified.
Provide Phase 1 recall switch at main floor elevator lobby and fire control life safety room. Key switches at main floor shall be integrated in hall button station hoistway entrance jamb with engraved instructions.
Elevator No. ALL: Provide new heavy-duty master type solid state closed loop door operators mounted on car enclosure utilizing minimum 12-guage support angles to isolate from direct mounting of operator on the car top.
Elevator Nos. below: Provide new extruded sills with non-slip surfaces and grooves suitable for guides. Extend strut to strut and mount with concealed fasteners.
+6 more items
Cab & Entrance
13 itemsCab interiors, finishes, and entrance assemblies
Hotel Tower 1: Modernize elevator nos. TP1-TP6 with new controls, new gearless machines, positioning system, door operators and equipment, governor, signals and fixtures, hoistway wiring, cab interiors, and recondition other equipment as specified.
Hotel BOH: Modernize elevator nos. BRS1, BRS2, EP1 and EP2 with new MRL gearless machines, new controllers, positioning system, door operators and equipment, hall door equipment, signals and fixtures, hoistway wiring, cab components and recondition other equipment as specified.
Hotel BOH: Modernize elevator no. BRF1 with new gearled machine, new controller, positioning system, door operators and equipment, hall door equipment, signals and fixtures, hoistway wiring, cab components and recondition other equipment as specified.
Restaurant Kitchens: Modernize elevator nos. KS2, KS3, KS4, KS5, KS7 with new controls, new pumping units, positioning system, door operators and equipment, signals and fixtures, hoistway wiring, cab components, and recondition other equipment as specified.
Theatre: Modernize elevator no. CTS1 with new pumping unit and tank, new controls, positioning system, door operator and equipment, signals and fixtures, hoistway wiring, cab components and recondition other equipment as specified.
Provide add for one (1) new 15 inch Elite Display in each cab. Provide a USB port in the service cabinet for content load up. Provide for elevators TP1-TP10, CTP1, CP1-CP2, WG1-WG2, EPP1-EPP4, WPP1- WPP4.
Service Cabinet: Provide New
Corporate Center #1-4: Provide add for one (1) new 12.1 inch Elite Display in each cab. Provide a USB port in the service cabinet for content load up.
+5 more items
Signal Fixtures
2 itemsHall stations, indicators, COPs, and signage
Car Operating Panels: Provide New
Car Position Indicators: Provide New Hall Position Indicators: Provide New
Machines & Motors
15 itemsTraction machines, motors, ropes, and governors
Hotel Tower 1: Modernize elevator nos. TP1-TP6 with new controls, new gearless machines, positioning system, door operators and equipment, governor, signals and fixtures, hoistway wiring, cab interiors, and recondition other equipment as specified.
Hotel BOH: Modernize elevator nos. BRS1, BRS2, EP1 and EP2 with new MRL gearless machines, new controllers, positioning system, door operators and equipment, hall door equipment, signals and fixtures, hoistway wiring, cab components and recondition other equipment as specified.
Hotel BOH: Modernize elevator no. BRF1 with new gearled machine, new controller, positioning system, door operators and equipment, hall door equipment, signals and fixtures, hoistway wiring, cab components and recondition other equipment as specified.
Restaurant Kitchens: Modernize elevator nos. KS2, KS3, KS4, KS5, KS7 with new controls, new pumping units, positioning system, door operators and equipment, signals and fixtures, hoistway wiring, cab components, and recondition other equipment as specified.
Theatre: Modernize elevator no. CTS1 with new pumping unit and tank, new controls, positioning system, door operator and equipment, signals and fixtures, hoistway wiring, cab components and recondition other equipment as specified.
For traction machines, employ a Structural Engineer to study the machine room floor and wall support. Any machines beams can be added.
Provide split unit AC for #CTP1 machine room. Assume the remaining machine rooms are properly cooled.
Hoist Ropes: Provide New, Provide Rope Lubricators
+7 more items
Safety Equipment
7 itemsSafeties, governors, buffers, and seismic devices
Hotel Tower 1: Modernize elevator nos. TP1-TP6 with new controls, new gearless machines, positioning system, door operators and equipment, governor, signals and fixtures, hoistway wiring, cab interiors, and recondition other equipment as specified.
Governor Ropes: Provide New
Provide a dual ring and string, continuously monitoring type counterweight displacement device for each counterweight with rings mounted on each corner of frame. Provide a seismic switch device measuring both horizontal and vertical accelerations for each group of elevators.
Provide Phase 1 recall switch at main floor elevator lobby and fire control life safety room. Key switches at main floor shall be integrated in hall button station hoistway entrance jamb with engraved instructions.
Elevator No. ALL: Retain existing oil buffers. Replace seals, clean ram and apply machinist blue dye, readjust to car buffer plates, drain and flush out all oil tanks, clean down, refill and test with full load at contract speed.
Elevator No. ALL: Retain existing, realign, correct balance, clean down and tighten frame bolts. Provide retainer plates to meet seismic code requirements.
Provide new ascending car protection that detects an ascending car over-speed condition at a speed not greater than 10% higher than the speed at which the car governor is set to trip.
Electrical
8 itemsTraveling cables, wiring, and electrical components
Hotel Tower 1: Modernize elevator nos. TP1-TP6 with new controls, new gearless machines, positioning system, door operators and equipment, governor, signals and fixtures, hoistway wiring, cab interiors, and recondition other equipment as specified.
Hotel BOH: Modernize elevator nos. BRS1, BRS2, EP1 and EP2 with new MRL gearless machines, new controllers, positioning system, door operators and equipment, hall door equipment, signals and fixtures, hoistway wiring, cab components and recondition other equipment as specified.
Hotel BOH: Modernize elevator no. BRF1 with new gearled machine, new controller, positioning system, door operators and equipment, hall door equipment, signals and fixtures, hoistway wiring, cab components and recondition other equipment as specified.
Restaurant Kitchens: Modernize elevator nos. KS2, KS3, KS4, KS5, KS7 with new controls, new pumping units, positioning system, door operators and equipment, signals and fixtures, hoistway wiring, cab components, and recondition other equipment as specified.
Theatre: Modernize elevator no. CTS1 with new pumping unit and tank, new controls, positioning system, door operator and equipment, signals and fixtures, hoistway wiring, cab components and recondition other equipment as specified.
Communication circuit: Telephone circuit terminated at junction box of each controller.
Provide a complete Voice Annunciation Unit (including the Device, the Wiring to the elevator cab, Speaker and Control System Software designed to include a Voice Annunciation Interface).
Provide for elevators as scheduled. When power is lost in a building, the unit will disconnect the elevator system from the building power source. It will then power up its inverter and provide battery generated three (3) phase power to the elevator controller.
Specialty
2 itemsCommunication systems, fire service, and access control
Communication circuit: Telephone circuit terminated at junction box of each controller.
Communications: Provide New